Getting Start
nlscan.com
Page 15
Code Programming ON
Code Programming OFF
Tools
Reading Mode
Mode Selection
Hand-held Mode: press and keep holding the trigger to read. Complete one reading or »
release the trigger to terminate reading status.
Sensor Mode: the environmental luminance changing in front of the engine
»
automatically initiates reading status. Complete one reading to terminate reading and switch
to idle. Both luminance changing and the Trigger can initiate reading when idle.
Cont
inuous Mode: one hit the Trigger to start continuous reading, and on hit to »
terminate reading.
** Hand-held Mode
Pro CMD0302000
Sensor Mode
Pro CMD0302010
Continuous Mode
Pro CMD0302020
Sensor Mode Timeout
When the engine reading at Sensor Mode, the period of time before automatically switch to idle is Sensor Mode
Timeout. The timeout counts from the latest environmental lamination change. Notice that a reading completed will
terminate reading status. Default timeout = 2000 ms.
Sensor Mode Timeout
Pro CMD0313000