Code 128
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is
less than Min Message Length, it means the engine will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the engine will only sup-
port barcodes of the length.
To set Min Message Length of Code 128 to 8 bytes and Max Message Length to 12 bytes,
read these programming codes
Code Programming ON 1
Select Min Message Length 2
Digit Code 8, see Digit Code 3
Save Programming, see Digit Code 4
Select Max Message Length 5
Digit Code 1 6
Digit Code 2 7
Save Programming 8
Code Programming OFF 9
Select Message Length
It is used to program the valid reading length of Code 128. The engine will
send an error beep, if the decoded data length does not match the valid
length.
Code 128 Message Length is dened by Min. Message Length and
Max. Message Length.
Min Message Length
Pro CMD99910003
Max Message Length
Pro CMD99910004